CHANGE OF GAS
Your cooker is foreseen to work with G20 to
20 mbar.
Your cooker is foreseen to work with natural
gas, propane or butane. It is not foreseen
for butane or propane air.
For changing the gas type it is necessary to:
replace the nozzles (hob, oven and
grill);
adjust the minimum level (hob and
oven);
adjust the primary air (oven and grill)
check the gas connection
Replace the nozzles of the hob burners
Every appliance has spare nozzles for every
gas. The whole of every nozzle is marked in
millimeters on the nozzle.
Hob burners
- Remove the pan support;
- Extract the caps and the wall baffles of
the burners;
- Using a socket spanner 7 unscrew the
nozzles and replace them with those
required for the type of gas in use (see
table no. 1).
Reassemble the parts following the same
procedure backwards.
These burners don’t need any primary air
regulation.
Adjustment of minimum level for the
hob burners
The burner is well adjusted when the flame
is stable silent ant dies out without any
noise.
When changing the gas type check that the
minimum be correct. The air admission is
correct when the flame is about 4 mm
length.
The top burners do not need adjustment of
primary air.
Check that, turning quickly the knob from
the maximum position to the minimum one,
the flame does not go out.
Vista de pagina 21